Coil calculator.
Turn coil weight into linear feet and square feet, or work it backward. Then estimate the clips for a standing seam roof.
Weight, length and square feet
Pick the metal, the gauge and the coil width, then enter what you know. The numbers update as you type.
Uses nominal thickness for each gauge and standard densities (steel 0.2836, aluminum 0.0975, copper 0.323 lb per cubic inch). Real coils vary a little, so use the mill cert or the coil tag for anything you’re billing.
How many clips for a standing seam roof
Enter the panel coverage, the total length of panel and the clip spacing.
Clips = total panel length × 12 ÷ spacing. Add extras for starts, ends and high wind zones. Clip spacing comes from the PAC-CLAD load table for your panel and wind load, so check it before you order.
PAC-CLAD panels and details
Clip spacing and coverage come from the panel you pick. See them on the PAC-CLAD overview.
Send us the numbers
Call Amy at 615-961-8470 with your coil width, gauge and color, or send a takeoff with an order form.
615-961-8470